Conduit/ Innerduct

 Smoothwall Innerduct/Conduit HDPE

Conduit for your Telecom, Cable, DOT or Enterprise needs available in multiple sizes and lengths, please consult the charts below or call Mohawk Ltd. with your specific needs.


• Manufactured from flexible HDPE, makes gradual bends without special equipment

• Continuous lengths reduce joining costs

• Excellent low temperature properties, allows installation in cold climates

• Outstanding long term cable protection from shifting ground, rock and root impingement

• Provides a permanent pathway, simplifies future cable repairs or replacement

• Available with UV protectant for aerial/lashed placement

• Optional Mule Tape / Conduit Measuring Tape Available

Note: Standard Dimension Ratio (SDR SDIR) Is the ratio of the inside diameter of the duct or innerduct to the wall thickness of the duct or innerduct. The smaller the SDR number the thicker the wall of the duct.

SDR Conduit/Innerduct

Pipe Size
3/4″
1″
Wall Type
Nom OD (in)
1.050
1.315
OD Tolerance +/-
0.005
0.007
Bend Radius (in) Supported
10
13
Bend Radius (in) Unsupported
20
26
SDR-11
Min Wall (in)
0.095
0.120
Wall Tolerance +
0.020
0.020
Avg ID (in)
0.840
1.055
Weight (#ft)
0.128
0.199
Safe Working Load
687
1,078
SDR-13.5
Min Wall (in)
0.078
0.097
Wall Tolerance +
0.020
0.020
Avg ID (in)
0.874
1.101
Weight (#ft)
0.110
0.167
Safe Working Load
570
894

SIDR Conduit/Innerduct

Pipe Size
3/4″
1″
Wall Type
Nom OD (in)
0.824
1.049
OD Tolerance +
0.010
0.010
OD Tolerance –
0.010
0.015
Bend Radius (in) Supported
8
10
Bend Radius (in) Unsupported
16
20
SIDR-11.5
Min Wall (in)
0.072
0.091
Wall Tolerance +
0.020
0.020
Avg ID (in)
0.986
1.246
Weight (#ft)
0.096
0.150
Safe Working Load
597
891

SCH Conduit/Innerduct

Pipe Size
4″
Wall Type
Nom OD (in)
4.500
OD Tolerance +
0.023
Bend Radius (in) Supported
50
Bend Radius (in) Unsupported
100
SCH-40
Min Wall (in)
0.237
Wall Tolerance +
0.028
Avg ID (in)
3.998
Weight (#ft)
1.30
Safe Working Load
7,618

 

Request Quotation Conduit SDR or SIDR

Phone number (optional but helps)
Conduit Type
Please enter length in feet